AJIC: American Journal of Infection Control
Volume 37, Issue 5 , Pages 381-386, June 2009

Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage

  • Dennis J. Viscusi, BS

      Affiliations

    • National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA
  • ,
  • Mike Bergman, MS

      Affiliations

    • EG&G Technical Services, Inc, Pittsburgh, PA
  • ,
  • Edward Sinkule, MS

      Affiliations

    • National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA
  • ,
  • Ronald E. Shaffer, PhD

      Affiliations

    • National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA
    • Corresponding Author InformationAddress correspondence to Ronald E. Shaffer, PhD, Chief, Technology Research Branch, National Personal Protective Technology Lab (NPPTL), National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), 626 Cochrans Mill Road, Building 29, P.O. Box 18070, Pittsburgh, PA 15236.

published online 02 February 2009.

Background

Organizations are stockpiling respirators to prepare for an influenza pandemic. To understand better the effects of prolonged storage, this investigation evaluated the filtration efficiency of 21 different models of National Institute for Occupational Safety and Health (NIOSH)-certified disposable N95 filtering face piece respirators. These respirators had been stored in their original packaging for a period of at least 6 years in research laboratories and dry warehouse facilities, ranging in temperature between 15°C and 32°C and relative humidity between 20% and 80%.

Methods

Filter penetration was measured using an abbreviated version of the NIOSH respirator certification test incorporating a polydisperse sodium chloride aerosol at 85 L/min.

Results

Of the 21 respirator models tested, 19 models had both average penetration results of less than 5%. Mean initial penetration values ranged from 0.39% to 5.83%, whereas mean maximum penetration values ranged from 0.95% to 5.83%. There did not appear to be any correlation between the length of storage and failure to pass the filtration test.

Conclusion

Results indicate that most N95 filtering face piece respirators stored for up to 10 years at warehouse conditions will likely have expected levels of filtration performance and that the degree of filtration efficiency degradation is likely model specific.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 12.00 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health (NIOSH). Mention of company names or products does not constitute endorsement by NIOSH.

 Conflicts of interest: None to report.

PII: S0196-6553(08)00853-5

doi:10.1016/j.ajic.2008.09.021

AJIC: American Journal of Infection Control
Volume 37, Issue 5 , Pages 381-386, June 2009