AJIC: American Journal of Infection Control
Volume 37, Issue 5 , Pages 381-386 , June 2009

Evaluation of the filtration performance of 21 N95 filtering face piece respirators after prolonged storage

  • Dennis J. Viscusi, BS

      Affiliations

    • National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA
  • ,
  • Mike Bergman, MS

      Affiliations

    • EG&G Technical Services, Inc, Pittsburgh, PA
  • ,
  • Edward Sinkule, MS

      Affiliations

    • National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA
  • ,
  • Ronald E. Shaffer, PhD

      Affiliations

    • National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA
    • Corresponding Author InformationAddress correspondence to Ronald E. Shaffer, PhD, Chief, Technology Research Branch, National Personal Protective Technology Lab (NPPTL), National Institute for Occupational Safety and Health (NIOSH), Centers for Disease Control and Prevention (CDC), 626 Cochrans Mill Road, Building 29, P.O. Box 18070, Pittsburgh, PA 15236.

References 

  1. Institute of Medicine (US). Reusability of facemasks during an influenza pandemic. Washington: The Institute; 2006;
  2. Rubinson L, Nuzzo JB, Talmor DS. Augmentation of hospital critical care capacity after bioterrorist attacks or epidemics: recommendations of the Working Group on Emergency Mass Critical Care. Crit Care Med. 2005;33(Suppl):E2393
  3. Schmit J. Disposable respirator demand on rise. USA TODAY 2006 August 17. Available at: http://www.usatoday.com/money/industries/health/2006-08-17-n95-masks-usat_x.htm. Accessed May 14, 2008.
  4. Roberge R. Effect of surgical masks worn concurrently over N95 filtering facepiece respirators: extended service life versus increased user burden. J Pub Health Manage. 2008;14:E19–E26
  5. Hinds WC. Aerosol technology: properties, behavior, and measurements of airborne particles. 2nd ed.. New York: Wiley; 1998;p. 196
  6. Barrett LW, Rousseau AD. Aerosol loading performance of electret filter media. Am Indust Hyg Assoc J. 1998;59(8):532–539
  7. Janssen LL, Bidwell JO. Mullins, HE, Nelson TJ. Efficiency of degraded electret filters: part II. Field testing against workplace aerosols. J Int Soc Resp Protect. 2003;20(2):81–90
  8. Martin SB, Moyer E. Electrostatic respirator filter media: filter efficiency and most penetrating particle size effects. Appl Occup Environ Hyg. 2000;15:609–617
  9. Jasper W, Hinestroza J, Mohan A, Thompson D, Barker R. Effect of phase of toluene on filtration performance of electret filter media against di-octyl-phthalate aerosols. J Int Soc Resp Protect. 2005;22:97–105
  10. Jasper W, Hinestroza J, Mohan A, Kim J, Shiels B, Gunay M, et al. Effect of xylene exposure on the performance of electret filter media. J Aerosol Sci. 2006;37:903–911
  11. Viscusi DJ, King WP, Shaffer RE. Effect of decontamination on the filtration efficiency of two filtering facepiece respirator models. J Int Soc Resp Protect. 2007;24:93–107
  12. Moyer ES, Bergman MS. Electrostatic N-95 respirator filter media efficiency degradation resulting from intermittent sodium chloride aerosol exposure. Appl Occup Environ Hyg. 2000;15:600–608
  13. Kanaoka C, Emi H, Ishiguro T. Time dependency of collection performance of electret filter. In: Liu BYH, Pui DYH, Fissan HJ, editors. New York: Elsevier; p. 613–616.
  14. Walsh DC, Stenhouse JIT. Parameters affecting the loading behavior and degradation of electrically active filter materials. Aerosol Sci Tech. 1998;29(5):419–432
  15. Janssen LL, Bidwell JO, Mullins HE, Nelson TJ. Efficiency of degraded electret filters: part I. Laboratory testing against NaCl and DOP before and after exposure to workplace aerosols. J Int Soc Resp Protect. 2003;20(2):71–80
  16. Ackley MW. Degradation of electrostatic filters at elevated temperature and humidity. Filtration Separation. 1982;22:239–242
  17. Van Turnhout J. Electret split fibers for high-efficiency filtration of polluted air. Proceedings of the First International Symposium On Electrets and Dialectics. Brazil: Sao Carlos; 1975;p. 87-96
  18. Van Turnhout J, Van Bochave C, Van Veldhulzen GJ. Electret fibers for high-efficiency filtration of polluted gases. Staub-Reinhart der Luft. 1976;36:36–39
  19. Motyl E, Lowkis B. Effect of air humidity on charge decay and lifetime of PP electret nonwovens. Fibres & Textiles in Eastern Europe. 2006;14:39–42
  20. Respiratory protection. 29 C.F.R. §1910.134. 1998. Available at: http://frwebgate.access.gpo.gov/cgi-bin/get-cfr.cgi. Accessed December 08, 2008.
  21. Approval of respiratory protective devices. 42 C.F.R. $84.180 & 84.181. 1995. Available at: http://www.access.gpo.gov/nara/cfr/waisidx_04/42cfr84_04.html. Accessed December 08, 2008.
  22. Johnson T, Smith S. Correlation of penetration results between filter testers that use different particle generators and detection methods. Proceedings of the 1998 Nonwovens Conference. March 9-11, 1998. St. Petersburg: FL. TAPPI; 1998;
  23. National Institute for Occupational Safety and Health (NIOSH). Procedure No. RCT-APR-STP-0057, 0058, 0059, Rev. 1.1. DHHS, Centers for Disease Control and Prevention; 2005. Available at: http://www.cdc.gov/niosh/npptl/stps/respirator_testing.htm. Accessed December 08, 2008.

 The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health (NIOSH). Mention of company names or products does not constitute endorsement by NIOSH.

 Conflicts of interest: None to report.

PII: S0196-6553(08)00853-5

doi: 10.1016/j.ajic.2008.09.021

AJIC: American Journal of Infection Control
Volume 37, Issue 5 , Pages 381-386 , June 2009