Advertisement
Article| Volume 12, ISSUE 5, P276-281, October 1984

Comparison of three methods of maintaining a sterile injectate system during cardiac output determinations

      This paper is only available as a PDF. To read, Please Download here.

      Abstract

      Current technique for determining cardiac output involves multiple manipulations of the injectate system and thereby raises the potential for serious infection. A randomized crossover study was undertaken to compare three methods for determining cardiac outputs, focusing on (1) ability to maintain sterile injectate, (2) operator time, and (3) cost effectiveness. The methods compared were the closed-loop injectate delivery, capped-syringe, and double-bag systems. Forty-five subjects were randomly assigned to one of three methods used, then “crossed over” to an alternate method. This resulted in six different groups: (1) 15 subjects assigned to closed loop first, then crossed over to double bag (eight) or capped syringe (seven), (2) 15 subjects assigned to double bag first, then crossed over to closed loop (seven) or capped syringe (eight), and (3) 15 subjects assigned to capped syringe first, then crossed over to double bag (seven) or closed loop (eight). Quantitative cultures of sample injectates served as indicators of contamination. The Wilcoxon signed rank analysis showed no statistical difference (p > 0.9) in patient or catheter caracteristics between treatment groups. None of 30 cultures from the closed-loop method yielded bacterial growth, compared to 6 of the 30 cultures positive from each of the other methods (p < 0.0001). The closed-loop method also required less operator time and was more cost effective than the two alternate methods examined.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Infection Control
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Ganz W.
        • Donoso R.
        • Marcus H.S.
        • Forrester J.S.
        • Swan H.J.C.
        New technique for measurement of cardiac output by thermodilution in man.
        Am J Cardiol. 1971; 27: 392-396
        • Weisel R.D.
        • Berger R.L.
        • Hechtman H.B.
        Measurement of cardiac output by thermodilution.
        N Engl J Med. 1975; 292: 682-684
        • Michel L.
        • Marsh H.M.
        • McMichan J.C.
        • Southorn P.A.
        • Brewer N.S.
        Infection of pulmonary artery catheters in critically ill patients.
        JAMA. 1981; 245: 1032-1035
        • Kinney M.
        • Dear C.
        • Packa L.B.
        • Voorman D.R.
        • Wagelhout D.M.
        AACN clinical reference for critical care nursing.
        McGraw-Hill Book Co, New York1981
        • Cole R.
        • Carlon G.C.
        • Campfield P.B.
        • Turnbull A.D.
        Multiple determinations of cardiac output using a two-bottle technique.
        Crit Care Med. 1979; 7: 33-34
        • Lennette E.H.
        • Spaulding E.H.
        • Truant J.P.
        Manual of clinical microbiology. ed 2. American Society for Microbiology, Washington, DC1974
        • Maki D.G.
        Epidemic nosocomial bacteremias (chart).
        in: ed. 8. CRC handbook of hospital acquired infections. CRC Press Inc, Boca Raton1981
        • Elliott C.G.
        • Zimmerman G.A.
        • Clemmer T.P.
        Complications of pulmonary artery catheterization in the care of critically ill patients.
        Chest. 1979; 76: 647-652