Advertisement

Evaluation of an automated ultraviolet-C light disinfection device and patient hand hygiene for reduction of pathogen transfer from interactive touchscreen computer kiosks

Published:November 22, 2017DOI:https://doi.org/10.1016/j.ajic.2017.09.032
      Touchscreens are a potential source of pathogen transmission. In our facility, patients and visitors rarely perform hand hygiene after using interactive touchscreen computer kiosks. An automated ultraviolet-C touchscreen disinfection device was effective in reducing bacteriophage MS2, bacteriophage ϕX174, methicillin-resistant Staphylococcus aureus, and Clostridium difficile spores inoculated onto a touchscreen. In simulations, an automated ultraviolet-C touchscreen disinfection device alone or in combination with hand hygiene reduced transfer of the viruses from contaminated touchscreens to fingertips.

      Key Words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Infection Control
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Brady R.R.
        • Verran J.
        • Damani N.N.
        • Gibb A.P.
        Review of mobile communication devices as potential reservoirs of nosocomial pathogens.
        J Hosp Infect. 2009; 71: 295-300
        • Kiedrowski L.M.
        • Perisetti A.
        • Loock M.H.
        • Khaitsa M.L.
        • Guerrero D.M.
        Disinfection of iPad to reduce contamination with Clostridium difficile and methicillin-resistant Staphylococcus aureus.
        Am J Infect Control. 2013; 41: 1136-1137
        • Mathew J.I.
        • Cadnum J.L.
        • Sankar T.
        • Jencson A.L.
        • Kundrapu S.
        • Donskey C.J.
        Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.
        Am J Infect Control. 2016; 44: 724-726
        • Tomas M.E.
        • Kundrapu S.
        • Thota P.
        • Sunkesula V.C.
        • Cadnum J.L.
        • Mana T.S.
        • et al.
        Contamination of the skin and clothing of healthcare personnel during removal of personal protective equipment.
        JAMA Intern Med. 2015; 175: 1904-1910
        • Casanova L.M.
        • Teal L.J.
        • Sickbert-Bennett E.E.
        • Anderson D.J.
        • Sexton D.J.
        • Rutala W.A.
        • et al.
        Assessment of self-contamination during removal of personal protective equipment for Ebola patient care.
        Infect Control Hosp Epidemiol. 2016; 37: 1156-1161
        • Alhmidi H.
        • John A.
        • Mana T.C.
        • Koganti S.
        • Cadnum J.L.
        • Shelton M.B.
        • et al.
        Evaluation of viral surrogate markers for study of pathogen dissemination during simulations of patient care.
        Open Forum Infect Dis. 2017; 4 (ofx128)
        • Sickbert-Bennett E.E.
        • Weber D.J.
        • Gergen-Teague M.F.
        • Sobsey M.D.
        • Samsa G.P.
        • Rutala W.A.
        Comparative efficacy of hand hygiene agents in the reduction of bacteria and viruses.
        Am J Infect Control. 2005; 33: 67-77
        • Cadnum J.L.
        • Tomas M.E.
        • Sankar T.
        • Jencson A.
        • Mathew J.I.
        • Kundrapu S.
        • et al.
        Effect of variation in test methods on performance of ultraviolet-C radiation room decontamination.
        Infect Control Hosp Epidemiol. 2016; 37: 555-560
        • Apple Inc
        Cleaning your Apple products.
        (Available from:)
        http://support.apple.com/kb/ht3226
        Date accessed: April 15, 2013
        • Gerba C.P.
        • Wuollet A.L.
        • Raisanen P.
        • Lopez G.U.
        Bacterial contamination of computer touch screens.
        Am J Infect Control. 2016; 44: 358-360