Focused multivector ultraviolet (FMUV) technology rapidly eradicates SARS-CoV-2 in-vitro: Implications for hospital disinfection of COVID-19 environments

Published:February 10, 2022DOI:https://doi.org/10.1016/j.ajic.2022.02.001

      Highlights

      • Focused Multivector Ultraviolet technology rapidly killed the SARS-CoV-2 in-vitro.
      • Mean reductions of 99.9999% SARS-CoV-2 were achieved within 90 seconds.
      • Focused Multivector Ultraviolet technology is effective for SARS-CoV-2 disinfection.

      Abstract

      Focused Multivector Ultraviolet technology rapidly killed the SARS-CoV-2 coronavirus in-vitro. Plates were inoculated with a mean of greater than 106 plaque forming units of USA-WA1 Washington index patient strain of SARS-CoV-2 and exposed to ultraviolet, resulting in mean reductions of 99.99% within 30 seconds, 99.999% within 60 seconds, and 99.9999% within 90 seconds. These results support the effectiveness of Focused Multivector Ultraviolet technology for SARS-CoV-2 disinfection.

      Key words

      Hospitals worldwide have suffered the effects of the COVID-19 pandemic. Surface contamination by SARS-CoV-2 is a prevalent problem in hospitals caring for COVID-19 patients,
      • Chia PY
      • Coleman KK
      • Tan YK
      • et al.
      Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients.
      and has been noted as a potential source of transmission.
      • Kanamori H.
      An overview of research on air and environmental contamination with SARS-CoV-2 in healthcare settings.
      Chia et al. studied airborne infection isolation rooms where patients with COVID-19 were hospitalized and found high touch surface contamination in 66.7% of patient rooms in the first week of illness.
      • Chia PY
      • Coleman KK
      • Tan YK
      • et al.
      Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients.
      Additionally, an overview study showed SARS-CoV-2 viral particles extensively contaminated both the air and surfaces in rooms of COVID-19 patients. For all instances where air samples were positive for SARS-CoV-2 RNA, environmental surface samples were also positive.
      • Kanamori H.
      An overview of research on air and environmental contamination with SARS-CoV-2 in healthcare settings.
      Several studies have demonstrated the activity of ultraviolet-C (UV-C) against SARS-CoV-2.
      • Gidari A
      • Sabbatini S
      • Bastianelli S
      • et al.
      SARS-CoV-2 survival on surfaces and the effect of UV-C light.
      • Heilingloh CS
      • Aufderhorst UW
      • Schipper L
      • et al.
      Susceptibility of SARS-CoV-2 to UV irradiation.
      • Biasin M
      • Bianco A
      • Pareschi G
      • et al.
      UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication.
      However, the test conditions utilized do not easily translate to the hospital environment. UV instruments using a single lamp or centralized source of lamps lose microbicidal activity as an inverse function of the radial distance from the source (1/r2), while also being limited by shadowing effects for 3-dimensional surfaces. However, Focused Multivector Ultraviolet (FMUV) systems sustain high UV-C energy levels in the exposure field and overcome shadowing by virtue of the technology's method of light delivery from multiple sources. FMUV has been previously shown as an automated approach for overcoming inconsistencies inherent to manual cleaning.
      • Armellino D
      • Goldstein K
      • Thomas L
      • Walsh TJ
      • Petraitis V.
      Comparative evaluation of operating room terminal cleaning by two methods: focused multivector ultraviolet (FMUV) versus manual-chemical disinfection.
      It was hypothesized that the technology being tested would rapidly eradicate SARS-CoV-2 in-vitro to document its efficacy for continued use in healthcare applications for environmental disinfection. Therefore, this study investigated the efficacy of FMUV for various exposure durations on a patient strain of SARS-CoV-2 in-vitro.

      Methods

      All stages of this study were conducted in a biosafety level 3 (BSL-3) facility at the Center for Discovery and Innovation according to strict biosafety guidelines.

      Inoculum preparation

      A solution of the USA-WA1 Washington index patient strain of SARS-CoV-2 stock was prepared in accordance with ASTM E1053 standards
      ASTM
      ASTM E1053-20, Standard Practice to Assess Virucidal Activity of Chemicals Intended for Disinfection of Inanimate, Nonporous Environmental Surfaces.
      in Dulbecco's Modified Eagle Medium +2% Fetal Bovine Serum with a titer of mean 1.125 × 106 PFU/mL for controls.

      Test configuration

      An FMUV system (PurpleSun Inc.) was deployed in a configuration to surround a 76 × 183 cm test table centered in the rectangular-shaped target zone at a 74 cm height (Fig 1). This zone is typically designated for disinfection of critical patient care equipment as large as patient beds and operating tables.
      • Armellino D
      • Goldstein K
      • Thomas L
      • Walsh TJ
      • Petraitis V.
      Comparative evaluation of operating room terminal cleaning by two methods: focused multivector ultraviolet (FMUV) versus manual-chemical disinfection.
      Fig 1
      Fig 1(A) Top view and (B) isometric view of the test equipment in rectangular configuration surrounding a table with triplicate test samples equally spaced in the center of the 195 × 140 × 274 cm FMUV target zone.

      Carrier preparation and FMUV exposure

      Glass slide carriers (25 × 75 × 1 mm) were cleaned, sterilized, placed within sterile Petri dishes, and inoculated with a 0.1 mL viral droplet. Due to BSL-3 safety and containment requirements, Petri dishes were covered with UV-transmissible material throughout the test, which were known to partially reduce UV exposure to the samples. Samples were exposed to FMUV light for durations of 0, 30, 45, and 90 seconds.

      Quantification

      After exposure, viral droplets were extracted from their carrier using a P200 pipette with a sterile aerosol barrier tip, diluted by a factor of 10, and assayed for infectivity in VeroE6 cells in Dulbecco's Modified Eagle Medium + Fetal Bovine Serum, supplemented with Penicillin, Streptomycin, and Amphotericin B. Cells were stained with 0.5% crystal violet, washed, and the detected number of viable organisms for each carrier was listed as plaque forming units (PFUs). Standard methods for data analysis and calculations were utilized to determine Log Reduction (LR) and Percent Reduction (PR).
      EPA
      Procedure for the OECD Quantitative Method for Testing Antimicrobial Products Against Spores of Clostridium difficile (ATCC 43598) on Inanimate, Hard, Non-porous Surfaces.

      Results

      Data from the plaque assay on virus infectivity at the given dilution is shown in Table 1.
      Table 1Results for individual and mean detected plaque forming units for all carriers when exposed to Focused Multivector Ultraviolet light for 0, 30, 45, and 90 seconds
      ConditionExposure time (s)Plaque forming units (PFU)Mean PFUPercent reduction
      Control Carriers0700,0001,300,000900,0001,60,00001,125,000N/A
      Test Carriers3080305053.3399.9954%
      4501003.3399.9994%
      90000099.9999%
      Current standards such as ASTM E2197 do not address methods for analyzing zero detected PFUs, such as observed here.
      ASTM
      E2197 - 17: Standard Quantitative Disk Carrier Test Method for Determining Bactericidal, Virucidal, Fungicidal, Mycobactericidal, and Sporicidal Activities of Chemicals.
      However, this is addressed in the Data Analysis section of Environmental Protection Agency MB-31-03, which was therefore used to compute the results. At a 10-fold dilution when a portion of carriers at a given time point showed zero, a value of 5 PFU/mL was used. The mean LR and PR was then calculated for the 30 seconds and 45 seconds time points. The standard further describes, for time points where zero PFUs are observed for all treated carriers, the LR and PR are recorded as ≥ the mean log10 density of the control carriers, which was followed for the 90 seconds time point.
      The germicidal activity of FMUV resulted in a mean 4-log reduction (99.9954%) of PFUs/carrier within 30 seconds, 5-log reduction (99.9994%) in 45 seconds, and ≥6-log reduction (≥99.9999%) in 90 seconds. Using the Aspin-Welch Test for Unequal Variance, P-values at all time points were .011, which is considered statistically significant.

      Discussion

      This study demonstrated rapid in-vitro eradication of viable SARS-CoV-2 within 90 seconds. To our knowledge, this is the first study to demonstrate a ≥6-log reduction of viable SARS-CoV-2 in a large-scale test setup within 90 seconds. One study reported a >6-log reduction after 540 seconds of UV exposure using one lamp at a 3 cm distance,
      • Heilingloh CS
      • Aufderhorst UW
      • Schipper L
      • et al.
      Susceptibility of SARS-CoV-2 to UV irradiation.
      while another described a >3-log reduction after 84.4 seconds also using one lamp at 25 cm.
      • Biasin M
      • Bianco A
      • Pareschi G
      • et al.
      UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication.
      The system employed in this study has been utilized in a wide range of hospital settings for equipment disinfection, especially between patient cases. Although this system is designed to treat equipment, the deployment wall and any other surfaces that are within the target zone will also disinfected. As United States hospitals become increasingly overwhelmed with variant COVID-19 cases, the need for rapid and effective disinfection is highlighted to properly facilitate safe patient room turnover. Though there is little in-vitro data on air disinfection of SARS-CoV-2 to date, pathogens are known to be more susceptible to UV-C in air than on surfaces or in liquid.
      • Kowalski WJ.
      Ultraviolet Germicidal Irradiation Handbook: UVGI for Air and Surface Disinfection, Chapter 4: UV Rate Constants).
      Furthermore, as this study demonstrated significant activity against the virus in-vitro suspended in a droplet on surfaces, the data suggests that this method of delivery would produce similar effects on aerosolized SARS-CoV-2 droplets.
      This study demonstrates FMUV rapidly reduced the SARS-CoV-2 coronavirus by ≥99.9999% within 90 seconds. Coupled with this technology's ability to treat equipment without requiring users to evacuate the room,
      • Armellino D
      • Goldstein K
      • Thomas L
      • Walsh TJ
      • Petraitis V.
      Comparative evaluation of operating room terminal cleaning by two methods: focused multivector ultraviolet (FMUV) versus manual-chemical disinfection.
      this data identifies FMUV as a potentially important approach to controlling COVID-19 in healthcare environments.

      Acknowledgments

      T.J.W. was supported by the Henry Schueler 41 & 9 Foundation for this work on COVID-19.

      References

        • Chia PY
        • Coleman KK
        • Tan YK
        • et al.
        Detection of air and surface contamination by SARS-CoV-2 in hospital rooms of infected patients.
        Nat Commun. 2020; 11: 2800
        • Kanamori H.
        An overview of research on air and environmental contamination with SARS-CoV-2 in healthcare settings.
        Infect Control Hosp Epidemiol. 2020; : 1-4
        • Gidari A
        • Sabbatini S
        • Bastianelli S
        • et al.
        SARS-CoV-2 survival on surfaces and the effect of UV-C light.
        Viruses. 2021; 13: 408
        • Heilingloh CS
        • Aufderhorst UW
        • Schipper L
        • et al.
        Susceptibility of SARS-CoV-2 to UV irradiation.
        Am J Infect Control. 2020; 48: 1273-1275
        • Biasin M
        • Bianco A
        • Pareschi G
        • et al.
        UV-C irradiation is highly effective in inactivating SARS-CoV-2 replication.
        Sci Rep. 2021; 11: 6260
        • Armellino D
        • Goldstein K
        • Thomas L
        • Walsh TJ
        • Petraitis V.
        Comparative evaluation of operating room terminal cleaning by two methods: focused multivector ultraviolet (FMUV) versus manual-chemical disinfection.
        Am J Infect Control. 2020; 48: 147-152
        • ASTM
        ASTM E1053-20, Standard Practice to Assess Virucidal Activity of Chemicals Intended for Disinfection of Inanimate, Nonporous Environmental Surfaces.
        ASTM International, 2011
        • EPA
        Procedure for the OECD Quantitative Method for Testing Antimicrobial Products Against Spores of Clostridium difficile (ATCC 43598) on Inanimate, Hard, Non-porous Surfaces.
        Environmental Protection Agency, 2017
        • ASTM
        E2197 - 17: Standard Quantitative Disk Carrier Test Method for Determining Bactericidal, Virucidal, Fungicidal, Mycobactericidal, and Sporicidal Activities of Chemicals.
        ASTM International, 2017
        • Kowalski WJ.
        Ultraviolet Germicidal Irradiation Handbook: UVGI for Air and Surface Disinfection, Chapter 4: UV Rate Constants).
        Springer, 2009