Advertisement

A cluster of gram-negative bloodstream infections in Connecticut hemodialysis patients associated with contaminated wall boxes and prime buckets

Published:August 12, 2022DOI:https://doi.org/10.1016/j.ajic.2022.08.007

      Highlights

      • A cluster of Delftia acidovorans infections occurred at a hemodialysis facility.
      • Delftia acidovorans was recovered from a wall box where 2 patients had been dialyzed.
      • Splashing of spent dialysate at wall boxes may have contaminated hands of personnel.
      • Contaminated saline prime bucket handles may also have been a source of infection.
      • Wall boxes should be disinfected at least daily, at the end of the day.

      Background

      Maintenance hemodialysis (HD) patients are at increased risk of bloodstream infections (BSI). We investigated a cluster of Delftia acidovorans infections among patients undergoing HD at an outpatient unit (Facility A).

      Methods

      A case was defined as a Facility A HD patient with ≥1 culture positive for D acidovorans between February 1 and April 30, 2018. An investigation included review of patient records, facility policies, practice observations, and environmental cultures.

      Results

      The cluster included 2 patients with confirmed D acidovorans BSI. Both patients had recently been dialyzed at Station #2, where a wall box culture yielded D acidovorans. One patient also had a BSI due to Enterobacter asburiae, which was recovered from several other wall boxes and saline prime buckets (SPB). Observations revealed leakage of wastewater from wall boxes onto the floor, and that SPBs were not always disinfected and dried appropriately before reuse. Multiple deficiencies in hand hygiene and station disinfection were observed. No deficiencies in water treatment practices were identified, and water cultures were negative for the observed pathogens.

      Conclusions

      The cluster of D acidovorans infections was most likely due to indirect exposures to contaminated wall boxes and possibly SPBs due to poor hand hygiene and station disinfection.

      Key Words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to American Journal of Infection Control
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • United States Renal Data System
        2020 USRDS Annual Data Report: Epidemiology of kidney disease in the United States. National Institutes of Health, National Institute of Diabetes and Digestive and Kindey Diseases.
        Bethesda, MD, 2020
        • Nguyen DB
        • Shugart A
        • Lines C
        • et al.
        National Healthcare Safety Network (NHSN) dialysis event surveillance report for 2014.
        Clin J Am Soc Nephrol. 2017; 12: 1139-1146
        • Beck-Sague CM
        • Jarvis WR
        • Bland LA
        • Arduino MJ
        • Aguero SM
        • Verosic G
        Outbreak of gram-negative bacteremia and pyrogenic reactions in a hemodialysis center.
        Am J Nephrol. 1990; 10: 397-403
        • Jackson BM
        • Beck-Sague CM
        • Bland LA
        • Arduino MJ
        • Meyer L
        • Jarvis WR
        Outbreak of pyrogenic reactions and gram-negative bacteremia in a hemodialysis center.
        Am J Nephrol. 1994; 14: 85-89
        • Coulliette AD
        • Arduino MJ.
        Hemodialysis and water quality.
        Semin.Dial. 2013; 26: 427-438
        • Flaherty JP
        • Garcia-Houchins S
        • Chudy R
        • Arnow PM.
        An outbreak of gram-negative bacteremia traced to contaminated O-rings in reprocessed dialyzers.
        Ann Intern Med. 1993; 119: 1072-1078
        • Welbel SF
        • Schoendorf K
        • Bland LA
        • et al.
        An outbreak of gram-negative bloodstream infections in chronic hemodialysis patients.
        Am J Nephrol. 1995; 15: 1-4
        • Oyong K
        • Marquez P
        • Terashita D
        • et al.
        Outbreak of bloodstream infections associated with multiuse dialyzers containing O-rings.
        Infect Control Hosp Epidemiol. 2014; 35: 89-91
        • Edens C
        • Wong J
        • Lyman M
        • et al.
        Hemodialyzer reuse and gram-negative bloodstream infections.
        Am J Kid Dis. 2017; 69: 726-733
        • Grohskopf LA
        • Roth VR
        • Feikin DR
        • et al.
        Serratia liquefaciens bloodstream infections from contamination of epoetin alfa at a hemodialysis center.
        N Engl J Med. 2001; 344: 1491-1497
        • Lanini S
        • Abbate I
        • Puro V
        • et al.
        Molecular epidemiology of a hepatitis C virus epidemic in a haemodialysis unit: outbreak investigation and infection outcome.
        BMC Infect Dis. 2010; 10: 257
        • Arnow PM
        • Garcia-Houchins S
        • Neagle MB
        • Bova JL
        • Dillon JJ
        • Chou T.
        An outbreak of bloodstream infections arising from hemodialysis equipment.
        J Infect Dis. 1998; 178: 783-791
        • Block C
        • Backenroth R
        • Gershon E
        • et al.
        Outbreak of bloodstream infections associated with dialysis machine waste ports in a hemodialysis facility.
        Eur J Clin Microbiol Infect Dis. 1999; 18: 723-725
        • Humar A
        • Oxley C
        • Sample ML
        • Garber G.
        Elimination of an outbreak of gram-negative bacteremia in a hemodialysis unit.
        Am J Infect Control. 1996; 24: 359-363
        • Jochimsen EM
        • Frenette C
        • Delorme M
        • et al.
        A cluster of bloodstream infections and pyrogenic reactions among hemodialysis patients traced to dialysis machine waste-handling option units.
        Am J Nephrol. 1998; 18: 485-489
        • Wang SA
        • Levine RB
        • Carson LA
        • et al.
        An outbreak of gram-negative bacteremia in hemodialysis patients traced to hemodialysis machine waste drain ports.
        Infect Control Hosp Epidemiol. 1999; 20: 746-751
        • Longfield RN
        • Wortham WG
        • Fletcher LL
        • Nauscheutz WF.
        Clustered bacteremias in a hemodialysis unit: cross-contamination of blood tubing from ultrafiltrate waste.
        Infect Control Hosp Epidemiol. 1992; 13: 160-164
        • Novosad SA
        • Lake J
        • Nguyen D
        • et al.
        Multicenter outbreak of gram-negative bloodstream infections in hemodialysis patients.
        Am J Kid Dis. 2019; 74: 610-619
        • Chotikanatis K
        • Backer M
        • Rosas-Garcia G
        • Hammerschlag MR.
        Recurrent intravascular-catheter-related bacteremia caused by Delftia acidovorans in a hemodialysis patient.
        J Clin Microbiol. 2011; 49: 3418-3421
        • American Public Health A, American Water Works A, Water Environment F
        Standard Methods for the Examination of Water and Wastewater.
        23rd ed. American Public Health Association; American Water Works Association; Water Environment Federation, Washington, DC2017 (Vol)
      1. Centers for Disease Control and Prevention. 2016 Update to the 2001 Recommendations for Preventing Transmission of Infections Among Chronic Hemodialysis Patients. In: Centers for Disease C, Prevention, eds. 2016.

        • Thompson ND
        • Novak RT
        • Datta D
        • et al.
        Hepatitis C virus transmission in hemodialysis units: importance of infection control practices and aseptic technique.
        Infect Control Hosp Epidemiol. 2009; 30: 900-903
        • Shimokura G
        • Chai F
        • Weber DJ
        • et al.
        Patient-care practices associated with an increased prevalence of hepatitis C virus infection among chronic hemodialysis patients.
        Infect Control Hosp Epidemiol. 2011; 32: 415-424
        • Nguyen DB
        • Gutowski J
        • Ghiselli M
        • et al.
        A large outbreak of hepatitis C virus infections in a hemodialysis clinic.
        Infect Control Hosp Epidemiol. 2016; 37: 125-133
        • Yassin MH
        • Abramovitz B
        • Hariri R
        • McKibben L
        • Pinevich AJ.
        Delftia acidovorans pseudo- outbreak in portable reverse osmosis machines: Interventions to ensure safe and cost-effective hemodialysis.
        Am J Infect Control. 2020; 48: 304-308
        • Rema T
        • Lawrence JR
        • Dynes JJ
        • Hitchcock AP
        • Korber DR.
        Microscopic and spectroscopic analyses of chlorhexidine tolerance in Delftia acidovorans biofilms.
        Antimicrob Agents Chemother. 2014; 58: 5673-5686
        • Stampi S
        • Zanetti F
        • Bergamaschi A
        • De LG.
        Comamonas acidovorans contamination of dental unit waters.
        Lett Appl Microbiol. 1999; 29: 52-55
        • Boyce JM
        • Dumigan DG
        • Havill NL
        • Hollis RJ
        • Pfaller MA
        • Moore BA.
        A multi-center outbreak of Candida tropicalis bloodstream infections associated with contaminated hemodialysis machine prime buckets.
        Am J Infect Control. 2021; 49: 1008-1013
        • Price CS
        • Hacek D
        • Noskin GA
        • Peterson LR.
        An outbreak of bloodstream infections in an outpatient hemodialysis center.
        Infect Control Hosp Epidemiol. 2002; 23: 725-729
        • Kliger AS
        • Garrick R.
        Targeting zero infections in hemodialysis.
        Am J Kid Dis. 2019; 74: 583-585
      2. Centers for Diseases Control and Prevention. Dialysis Safety. Dialysis wall boxes and drains. 2019. Accessed February 19, 2021. cdc.gov/dialysis/guidelines/wall-boxes.html..

      3. Strott K. ESRD NCC healthcare-associated infection (HAI) Learning and Action Network (LAN) discovery event. 2016. Accessed February 19, 2021,esrdncc.org/contentassets/66b85eda5c1948ae463410f1b3f8f6/ncc-discovery-event_120816_final_508.pdf. 2020.

        • Gualandi N.
        To boldly go where few have been before: Infection control assessment and response in the outpatient dialysis setting.
        in: Annual Council of State and Territorial Epidemiologists meeting; June 6, 2017, Boise, ID2017
      4. Hernandez jL, W.; Ridge, H. The North Carolina dialysis infection control assessment and response (ICAR) experience., 2018. Accessed February 19, 2021.network6.esrd.ipro.org/wp-content/uploads/sites/4/2016/06/ANNA-5-23-18-NC-SPICE-ICAR_Final.pdf.